Audio Seminars

Home | Contact Us | Newsletter | Usersclub | Books | Audio Seminars

All documents shown here are included in the seminar for instant download - and more

Adjusting Conditions for a Routine Reversed-Phase HPLC Assay,
Part II: Changing Separation Conditions (link)

1. How much can you change an official methods before it isn't the official method any more 

2. Analytical method validation - A Regulatory Perspective

System Suitability in HPLC Compendial Methods (H. Pappa)

Learn from FDA Warning Letters what inspectors look for and what mistakes other companies make so you can avoid them

Labcompliance On-line Audio Seminar

This seminar has been recorded and is available on CD and for instant download. All reference material as listed below and more is available on a special seminar website. The website is regularly updated with most recent information. In case there are questions related to the topic, they can be submitted through a web form and will be answered by the speaker. For ordering info click here.

On-line Audio Seminar 188

System Suitability in Chromatographic Compendial Methods

Understanding and Implementing Recent Changes of USP and EP

Recorded

Order Button

System suitability testing (SST) in chromatography is required by USP and FDA to check and ensure on-going performance of a chromatographic system. The USP has been updating requirements for SST in USP 30/2 (December 2007). The EP has been updated two years ago. With the increasing focus of the FDA on quality control laboratories inspectors ask for adequate SST procedures and whether analysts follow the procedures. The updated USP Chapter <621> also answers the question on how much a compendial procedure can be changed without the need for revalidation. Also, the new USP chapter <1058> makes a statement that SSTt may substitute an instrument's performance qualification, but not further guidelines are given. So there are many questions.      

Key questions related to system suitability testing are:

  • What are FDA requirements for SST?
  • What are the most frequently found deviations?
  • What are compendial requirements for SST?
  • What are the changes with the new chapter <621>
  • What is the significant differences between USP and EP?
  • When can SST substitute performance qualification (PQ)?
  • When should SST be conducted: before, in between or the end of a sequence?
  • We regularly run quality control samples, why do we need SST?
  • What are realistic test parameters and limits?
  • How much can I change a compendial method without revalidation?
  • How should we 'formally' document system suitability testing

How does the this audio seminar help:

Answers will be presented by Dr. Ludwig Huber in a new interactive audio seminar. During the seminar, the speaker will present strategies and give practical recommendations. After the seminar, an extensive list of reference material like SOPs and checklist will help immediate and cost effective implementation.

During the interactive presentation you learn about:

  • FDA and International requirements for system suitability testing
  • Examples of FDA warning letters and how to avoid them
  • The role of SST for analytical quality assurance
  • SST in comparison with equipment qualification and quality control sample analysis
  • Most critical parameters for SST in EP and USP
  • Contents of the updated USP chapter <621>
  • Recommendations for implementing the new <621>
  • Developing an SOP for system testing testing
  • Criteria for SST timing within a sequence of sample runs
  • The role of SST for method changes according to the new chapter <621>.
  • Criteria for revalidation for method changes
  • Case studies with practical advice for test parameters and limits
  • Documenting SST test runs

And for easy and instant implementation:
download 10+ documents from special seminar website

  • SOPS: 
    - System Suitability Testing in Chromatography
    - Change Versus Adjustment of Compendial Methods
  • Examples:
    - Protocols for Occasional  and Ongoing System Suitability Tests
    - Performance Qualification for HPLC
  • Templates/Checklist:
    - System Suitability Testing
    - Laboratory Audits
  • Reference article
    Adjusting Conditions for a Routine Reversed phase HPLC assay. Part II: Changing Separation Conditions
  • FDA Guidance: Analytical Procedures and Methods Validation
  • FDA and USP Presentations on method validation and System Suitability Testing
    - How Much Can You Change An Official Method Before It Isn‘t The Official Method Anymore? (T. Layloff, US-FDA)
    - HPLC Equipment Qualification, Includes recommendations for acceptance criteria
    - System Suitability Testing in HPLC Compendial Methods, H. Pappa, USP
  • ICH Guidelines for the Industry
    - Text on Validation of Analytical Procedures
    - Validation of Analytical Procedures: Methodology
  • Five Warning letters and/or Inspectional observations related to system suitability testing

Who should attend?

  • Everybody involved in system suitability testing
  • QA managers and personnel
  • Analysts and lab managers
  • Validation specialists
  • Training departments
  • Documentation department
  • Consultants

How to order

Pick one of the options in the table that fits your needs.

Recorded seminar - Web Download

  • Multiple persons - single site
  • Learn at your desk, meet in a seminar or conference room or share the audio file and reference material at your site.
  • Order includes all reference material.

US$ 399.-
Order Now Button

Recorded seminar - CD

  • Get the CD in your mail
  • Order includes all reference material.

US$ 399.-
Order Now Button

Special offer for Labcompliance Usersclub Members
Recorded Seminar- CD or Web download.

  • Order includes all reference material.
  • for Usersclub information and registration, click here

US$ 299.-
Order Now Button

About audio seminars

 

Online audio seminars are presented over the phone. During the live presentation attendees can:

  1. Study the printed slide material
  2. Watch the slides on a computer
  3. Watch the slides on a video screen in a seminar room
  4. Ask questions through email and web form

About Dr. Ludwig Huber

Dr. Ludwig Huber is the editor and author of Labcompliance. He has been conducting over 300 web and audio or video based seminars since 15 years and and he has given multiple presentations mainly on GLP/GMP, 21 CFR Part 11 and Validation around the world. This included seminars, workshops and presentations for the US FDA, SFDA, KFDA, HSA, ISPE, PDA, PIC/S and several national health agencies.

Dr. Ludwig Huber is a frequent presenter at IVT conferences and has been awarded as the 'Presenter of the Year' out of 170 speakers. This photo is from IVT's conference on Network Qualification with Ludwig Huber as plenary speaker.

Dr. Huber has published several books related to validation and compliance, for example: Validation of Computerized Analytical and Networked Systems. He was or still is a member of several committees, e.g., of the GAMP® Special interest group (SIG) on Laboratory Computers, PDA Part 11 task force, IVT task force on network infrastructure qualification and the European Compliance Academy. He frequently visited FDA in Rockville, VA, and participated in panel discussions with FDA professionals. For feedback from attendees of seminars and  for other information on Dr. Ludwig Huber, click here.